TEQ · Nasr City, Cairo

Mass and Balance Calibration in Egypt

Review separate published entries for on-site balance calibration and permanent-laboratory mass calibration. Include working loads or the nominal values of your weights in the quote request.

EGAC CAB 041701: accreditation applies to the activities, ranges, methods and locations in the current approved scope. Confirm the exact work with TEQ before ordering.

Define the calibration you need

Select balance calibration around the loads you actually weigh. Maximum capacity alone does not describe your measurement need: readability, working loads, tolerance and operating conditions all matter when reviewing a request. TEQ’s published balance entries are shown individually so you can check the relevant load band.

All eight balance entries below specify On-Site. State the installed location, floor or bench conditions, access and any constraints on bringing reference weights into the area. TEQ confirms the method, logistics and environmental suitability before scheduling work.

Reference weights are listed separately under mass calibration at the permanent laboratory. Provide each nominal value and weight class or other applicable specification. Confirm any separate minimum-weight assessment, legal-metrology requirement or statement of conformity with TEQ.

Published EGAC scope entries for these activities

These published entries describe the selected activities. Confirm the current accreditation status, exact instrument, requested points and service location with TEQ before ordering.

Source: EGAC CAB 041701 · Schedule 041701 B · Revision 01 ·

English technical labels are the controlling source transcription. Arabic labels are an informational reading aid. Numerical values, units, boundary symbols and source anomalies are retained as published.

Calibration CMCs are the scope-specific expanded uncertainty: k=2; approximately 95%. They are not a guaranteed uncertainty for every customer instrument. TEQ confirms the achievable uncertainty for the requested work.

Scroll inside the table to read every column. Source notes appear with the relevant instrument.

Selected EGAC scope entries · 8 published range/property entries
DisciplineInstrument / measurandRange / propertyCMC / uncertaintyReference methodLocation as publishedSource page
BalanceCalibration of Balances and Weighing InstrumentsCalibrationUp to 22 g10 μgOIML R76-1:2006On-SitePage 4
BalanceCalibration of Balances and Weighing InstrumentsCalibration>22 g to 220 g30 μgOIML R76-1:2006On-SitePage 4
BalanceCalibration of Balances and Weighing InstrumentsCalibration>220 g to 1000 g0.24 mgOIML R76-1:2006On-SitePage 4
BalanceCalibration of Balances and Weighing InstrumentsCalibration>1 kg to 10 kg4.0 mgOIML R76-1:2006On-SitePage 4
BalanceCalibration of Balances and Weighing InstrumentsCalibration>10 kg to 32 kg0.01 gOIML R76-1:2006On-SitePage 4
BalanceCalibration of Balances and Weighing InstrumentsCalibration>32 kg to 100 kg2.0 gOIML R76-1:2006On-SitePage 4
BalanceCalibration of Balances and Weighing InstrumentsCalibration>100 kg to 300 kg10 gOIML R76-1:2006On-SitePage 4
BalanceCalibration of Balances and Weighing InstrumentsCalibration>300 kg to 2000 kg0.10 kgOIML R76-1:2006On-SitePage 4

Published mass calibration at the permanent laboratory

These published entries describe the selected activities. Confirm the current accreditation status, exact instrument, requested points and service location with TEQ before ordering.

Source: EGAC CAB 041701 · Schedule 041701 B · Revision 01 ·

English technical labels are the controlling source transcription. Arabic labels are an informational reading aid. Numerical values, units, boundary symbols and source anomalies are retained as published.

Calibration CMCs are the scope-specific expanded uncertainty: k=2; approximately 95%. They are not a guaranteed uncertainty for every customer instrument. TEQ confirms the achievable uncertainty for the requested work.

Scroll inside the table to read every column. Source notes appear with the relevant instrument.

Selected EGAC scope entries · 14 published range/property entries
DisciplineInstrument / measurandRange / propertyCMC / uncertaintyReference methodLocation as publishedSource page
MassCalibration of MassCalibration1 mg to 20 mg1.3 μgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration50 mg to 200 mg2.0 μgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration500 mg2.5 μgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration1 g3.2 μgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration2 g to 5 g5.0 μgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration10 g to 20 g8.0 μgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration50 g13 μgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration100 g19 μgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration200 g32 μgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration500 g to 1000 g0.13 mgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration2 kg1.0 mgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration5 kg1.3 mgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration10 kg2.5 mgOIML R111:2004/ Amendment : 2025PermanentPage 5
MassCalibration of MassCalibration20 kg9.0 mgOIML R111:2004/ Amendment : 2025PermanentPage 5

What to include in your quotation request

  1. Balance manufacturer/model, serial or asset number, quantity, maximum capacity and displayed resolution.
  2. Normal working loads, calibration points, units and the measurement tolerance required by your process.
  3. Installed location, bench or foundation, warm-up arrangements and any vibration, airflow or temperature constraints.
  4. Access, lifting or handling needs for larger loads, site safety requirements and available calibration time.
  5. Required certificate details, adjustment permission and any conformity specification/decision rule. Ask TEQ to confirm the applicable scope band and achievable uncertainty.

Mass and Balance Calibration in Egypt: FAQs

Answers on scope, service location and preparing your request.

Where does TEQ’s published balance scope allow calibration?
The balance entries reproduced here state On-Site. TEQ must confirm the suitability of your installation, requested loads and conditions. These entries should not be relabelled as permanent-laboratory work.
Is balance readability the same as calibration uncertainty?
No. Readability is a display characteristic. The published CMC relates to laboratory calibration capability, while the uncertainty reported for a particular balance depends on the actual calibration. Specify your working loads and tolerance when requesting a quote.
Does a balance calibration certificate automatically establish a minimum weight?
Do not assume so. Tell TEQ the intended process, required relative uncertainty and any applicable procedure. Agree whether a separate minimum-weight assessment or conformity statement is required and available.