Mass and Balance Calibration in Egypt
Review separate published entries for on-site balance calibration and permanent-laboratory mass calibration. Include working loads or the nominal values of your weights in the quote request.
EGAC CAB 041701: accreditation applies to the activities, ranges, methods and locations in the current approved scope. Confirm the exact work with TEQ before ordering.
Define the calibration you need
Select balance calibration around the loads you actually weigh. Maximum capacity alone does not describe your measurement need: readability, working loads, tolerance and operating conditions all matter when reviewing a request. TEQ’s published balance entries are shown individually so you can check the relevant load band.
All eight balance entries below specify On-Site. State the installed location, floor or bench conditions, access and any constraints on bringing reference weights into the area. TEQ confirms the method, logistics and environmental suitability before scheduling work.
Reference weights are listed separately under mass calibration at the permanent laboratory. Provide each nominal value and weight class or other applicable specification. Confirm any separate minimum-weight assessment, legal-metrology requirement or statement of conformity with TEQ.
Published EGAC scope entries for these activities
These published entries describe the selected activities. Confirm the current accreditation status, exact instrument, requested points and service location with TEQ before ordering.
Source: EGAC CAB 041701 · Schedule 041701 B · Revision 01 ·
English technical labels are the controlling source transcription. Arabic labels are an informational reading aid. Numerical values, units, boundary symbols and source anomalies are retained as published.
Calibration CMCs are the scope-specific expanded uncertainty: k=2; approximately 95%. They are not a guaranteed uncertainty for every customer instrument. TEQ confirms the achievable uncertainty for the requested work.
Scroll inside the table to read every column. Source notes appear with the relevant instrument.
| Discipline | Instrument / measurand | Range / property | CMC / uncertainty | Reference method | Location as published | Source page |
|---|---|---|---|---|---|---|
| Balance | Calibration of Balances and Weighing InstrumentsCalibration | Up to 22 g | 10 μg | OIML R76-1:2006 | On-Site | Page 4 |
| Balance | Calibration of Balances and Weighing InstrumentsCalibration | >22 g to 220 g | 30 μg | OIML R76-1:2006 | On-Site | Page 4 |
| Balance | Calibration of Balances and Weighing InstrumentsCalibration | >220 g to 1000 g | 0.24 mg | OIML R76-1:2006 | On-Site | Page 4 |
| Balance | Calibration of Balances and Weighing InstrumentsCalibration | >1 kg to 10 kg | 4.0 mg | OIML R76-1:2006 | On-Site | Page 4 |
| Balance | Calibration of Balances and Weighing InstrumentsCalibration | >10 kg to 32 kg | 0.01 g | OIML R76-1:2006 | On-Site | Page 4 |
| Balance | Calibration of Balances and Weighing InstrumentsCalibration | >32 kg to 100 kg | 2.0 g | OIML R76-1:2006 | On-Site | Page 4 |
| Balance | Calibration of Balances and Weighing InstrumentsCalibration | >100 kg to 300 kg | 10 g | OIML R76-1:2006 | On-Site | Page 4 |
| Balance | Calibration of Balances and Weighing InstrumentsCalibration | >300 kg to 2000 kg | 0.10 kg | OIML R76-1:2006 | On-Site | Page 4 |
Published mass calibration at the permanent laboratory
These published entries describe the selected activities. Confirm the current accreditation status, exact instrument, requested points and service location with TEQ before ordering.
Source: EGAC CAB 041701 · Schedule 041701 B · Revision 01 ·
English technical labels are the controlling source transcription. Arabic labels are an informational reading aid. Numerical values, units, boundary symbols and source anomalies are retained as published.
Calibration CMCs are the scope-specific expanded uncertainty: k=2; approximately 95%. They are not a guaranteed uncertainty for every customer instrument. TEQ confirms the achievable uncertainty for the requested work.
Scroll inside the table to read every column. Source notes appear with the relevant instrument.
| Discipline | Instrument / measurand | Range / property | CMC / uncertainty | Reference method | Location as published | Source page |
|---|---|---|---|---|---|---|
| Mass | Calibration of MassCalibration | 1 mg to 20 mg | 1.3 μg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 50 mg to 200 mg | 2.0 μg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 500 mg | 2.5 μg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 1 g | 3.2 μg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 2 g to 5 g | 5.0 μg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 10 g to 20 g | 8.0 μg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 50 g | 13 μg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 100 g | 19 μg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 200 g | 32 μg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 500 g to 1000 g | 0.13 mg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 2 kg | 1.0 mg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 5 kg | 1.3 mg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 10 kg | 2.5 mg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
| Mass | Calibration of MassCalibration | 20 kg | 9.0 mg | OIML R111:2004/ Amendment : 2025 | Permanent | Page 5 |
What to include in your quotation request
- Balance manufacturer/model, serial or asset number, quantity, maximum capacity and displayed resolution.
- Normal working loads, calibration points, units and the measurement tolerance required by your process.
- Installed location, bench or foundation, warm-up arrangements and any vibration, airflow or temperature constraints.
- Access, lifting or handling needs for larger loads, site safety requirements and available calibration time.
- Required certificate details, adjustment permission and any conformity specification/decision rule. Ask TEQ to confirm the applicable scope band and achievable uncertainty.
Mass and Balance Calibration in Egypt: FAQs
Answers on scope, service location and preparing your request.