TEQ · Nasr City, Cairo

Pressure and Vacuum Calibration in Egypt

Request pressure-gauge calibration from TEQ in Cairo. Match vacuum, pneumatic or hydraulic work to the published range, measurement uncertainty and location before booking.

EGAC CAB 041701: accreditation applies to the activities, ranges, methods and locations in the current approved scope. Confirm the exact work with TEQ before ordering.

Define the calibration you need

A pressure enquiry starts with the medium and the instrument’s actual operating points. A vacuum gauge, a pneumatic gauge and a hydraulic gauge need different preparation. Send TEQ the dial or display details and the way you use the instrument so the quotation identifies the appropriate activity and measurement points.

The entries below list Permanent & On-Site. This describes the published scope location; a customer-site visit still depends on technical review, facilities, access and an agreed quotation. Tell TEQ whether the gauge can be removed safely or must be assessed at your facility.

The pressure-gauge calibration bands shown here are separate from safety/relief-valve testing. A testing range elsewhere in the schedule does not extend a gauge’s accredited calibration range. Request a separate review for transmitters, switches or functions not identified in these entries.

Published EGAC scope entries for these activities

These published entries describe the selected activities. Confirm the current accreditation status, exact instrument, requested points and service location with TEQ before ordering.

Source: EGAC CAB 041701 · Schedule 041701 B · Revision 01 ·

English technical labels are the controlling source transcription. Arabic labels are an informational reading aid. Numerical values, units, boundary symbols and source anomalies are retained as published.

Calibration CMCs are the scope-specific expanded uncertainty: k=2; approximately 95%. They are not a guaranteed uncertainty for every customer instrument. TEQ confirms the achievable uncertainty for the requested work.

Scroll inside the table to read every column. Source notes appear with the relevant instrument.

Selected EGAC scope entries · 5 published range/property entries
DisciplineInstrument / measurandRange / propertyCMC / uncertaintyReference methodLocation as publishedSource page
Pressure & VacuumCalibration of Vacuum Pressure GaugeCalibration-0.95 bar to 0 bar2.8 mbarDKD-R6-1-2014Permanent & On-SitePage 2
Pressure & VacuumCalibration of Pneumatic Pressure GaugeCalibrationUp to 20 bar2.9 mbarDKD-R6-1-2014Permanent & On-SitePage 2
Pressure & VacuumCalibration of Pneumatic Pressure GaugeCalibration>20 bar to 100 bar14 mbarDKD-R6-1-2014Permanent & On-SitePage 2
Pressure & VacuumCalibration of Hydraulic Pressure GaugeCalibrationUp to 700 bar0.1 barDKD-R6-1-2014Permanent & On-SitePage 2
Pressure & VacuumCalibration of Hydraulic Pressure GaugeCalibration>700 bar to 1000 bar0.26 barDKD-R6-1-2014Permanent & On-SitePage 2

What to include in your quotation request

  1. Manufacturer, model, asset number, quantity and a clear photograph of the scale or display.
  2. Vacuum, pneumatic or hydraulic duty; pressure units, full scale, actual working points and any required rising/falling sequence.
  3. Process medium, wetted-material constraints, cleanliness requirements and connection type or adapters.
  4. Required tolerance or uncertainty; identify the specification and decision rule if a conformity statement is requested.
  5. Laboratory delivery or site address, safe isolation arrangements and preferred dates. Ask TEQ to confirm scope, method, achievable uncertainty, price and turnaround.

Pressure and Vacuum Calibration in Egypt: FAQs

Answers on scope, service location and preparing your request.

Can TEQ calibrate my pressure gauge at my site in Egypt?
The listed pressure and vacuum entries include Permanent & On-Site. TEQ must first confirm the instrument, range, medium, required uncertainty and site conditions. The scope entry does not by itself confirm a visit date or suitability for every installation.
Does the lowest published CMC apply across the whole pressure range?
No. Each printed range has its own CMC. Read the appropriate row rather than applying one value across pneumatic and hydraulic bands. The uncertainty reported for your instrument also depends on the work performed.
Does pressure calibration include adjustment or a pass/fail statement?
Agree these separately in the quotation. State whether adjustment is permitted and whether you need as-found and as-left results. A conformity statement requires an agreed specification and decision rule.